A saddle takes a branch or service connection off a poly main without cutting the line. PLASSON makes mechanical saddles that bolt on and tap live, and electrofusion branch saddles that fuse on permanently — including large-bore saddles with a test port that make hot tapping on a pressurised line safer.
Plassaddle – metal-free mechanical saddle
The Plassaddle taps into a poly pipeline for irrigation, domestic and commercial connections. It installs fast, with no cutting equipment and minimal tools, and can go anywhere along the pipe. It taps live, is bolt-free, and has a built-in cutter.
Available in three offtakes: a female threaded offtake (ISO 7 “Rp”) in 1/2″, 3/4″, 1″, 1.1/4″ and 1.1/2″; a live tapper body with integral 25 or 32 mm Series 7 compression ends for PE or copper service pipe; and a live tapper with a 3/4″ male thread (ISO 7 “R”).
Spec
Pressure rating
Suitable pipe
Clamp
Body
Split ring
Seals
Cutter
Thread
Detail
Water PN16
PE100 and PE80; PE pipe to AS4130‚ PVC to CIOD (AS1477 series 2)
Glass-reinforced polypropylene
Polypropylene‚ high-grade copolymer (PPB)
Polyacetal
EPDM
Brass
ISO 7‚ type Rp (female) / R (male)
Electrofusion branch saddles
EF branch saddles fuse permanently onto the main in a single weld – the time-saving of one weld, the reliability of precision-moulded components, and a pressure test port for peace of mind. Large-bore branch saddles add a full-bore outlet for better flow and a larger fusion area.
Click here for more on electrofusion fittings, and here for more about PLASSON’s SmartFuse electrofusion range.
Spec
Weld data input
Pressure rating
Raw material
Voltage
Detail
Barcode or manual
Water PN16; gas PE100 SDR11
PE100
40 V ± 0.5 V
Hot tapping
Hot tapping means connecting to a pressurised, in-service line. PLASSON’s large-bore saddles are engineered to make this safer: the test port lets you confirm the integrity of the saddle weld before cutting into the pipe.
Visit our installation guides page for more video demonstrations and easy to follow installation sheets.
FAQ
What is a pipe saddle?
A fitting that takes a branch or service connection off a main without cutting the pipe. It clamps or fuses onto the pipe and cuts an outlet into it.
What’s the difference between a mechanical and an electrofusion saddle?
A mechanical saddle (Plassaddle) clamps on and taps live with a built-in cutter, no welding. An EF branch saddle fuses on permanently in a single weld.
What is hot tapping?
Connecting to a pressurised, in-service line. PLASSON’s large-bore saddles have a test port to check the weld before cutting in, which makes it safer.
What pressure are PLASSON saddles rated to?
Water PN16. EF branch saddles are also rated for gas at PE100 SDR11.
Choosing a saddle
Use the Product Finder, or call the team on 1300 752 776.